This page was exported from Braindump2go Free Exam Dumps with PDF and VCE Collection [ https://www.mcitpdump.com ] Export date:Thu Nov 21 19:17:39 2024 / +0000 GMT ___________________________________________________ Title: [2017-New-Version]100% Valid Network Appliance NS0-507 Dumps PDF and VCE 528Q Provided by Braindump2go[16-30] --------------------------------------------------- 2017 March NS0-507 Exam Dumps with PDF and VCE Free Released Today!Free Download NS0-507 Exam Dumps (PDF & VCE) 528Q&As (2017 Version!) from www.Braindump2go.com  Today! 100% Real Exam Questions! 100% Exam Pass Guaranteed! 1.|2017 Version NS0-507 Exam Dumps (PDF & VCE) 528Q&As Download:http://www.braindump2go.com/ns0-507.html 2.|2017 Version NS0-507 Exam Questions & Answers Download:https://1drv.ms/f/s!AvI7wzKf6QBjgnjcpE8O4Ejp86Pw QUESTION 16You currently have the following configuration on your cluster:cl01::>igroup show -¬instanceVserver Name: svm1Igroup Name: ig2Protocol: mixedOS Type: linuxPortset Binding Igroup: ¬-Igroup UUID: 3fb136c7¬-cfd6¬-11df¬-a9ab¬-123478563412 Initiators: ¬-What must you do to limit the LIFs that are used by an initiator to access a LUN? A.    Create a portset.B.    Create an additional igroup.C.    Change the protocol to iSCSI.D.    Change the OS type to windows_gpt. Answer: AExplanation:https://library.netapp.com/ecmdocs/ECMP1368525/html/GUID-5CC27202-A43F-429F-AB13-C70E7CD58E09.html QUESTION 17A customer has a 4-node cluster and wants to use iSCSI for LUN traffic.Which license needs to be installed on the nodes? A.    iSCSIB.    SnapRestoreC.    CIFSD.    FC Answer: A QUESTION 18Click the Exhibit button.cl01::>lun mapping show ¬-vserver svm1 ¬-path /vol/svm1_vol1/lun1 ¬-igroup svm1-ig1Vserver Name: svm1LUN path: /vol/svm1_vol1/lun1Volume Name: svm1_vol1Qtree Name: ""LUN Name: lun1Igroup Name: svm1-ig1Igroup OS Type: windowsIgroup Protocol Type: iscsiLUN ID: 3Portset Binding Igroup: -ALUA: trueInitiators: iqn.1991-05.com.microsoft: host1LUN Node: cl01-04Reporting Nodes: cl01-01,cl01-02, cl01-03, cl01-04You have a 2-node cluster. You have added an HA pair with all flash drives for a high-performance database that is currently experiencing performance problems on SAS drives. The LUN shown in the exhibit is moved from cl01-01 to cl01-04 to address the problems.What is the next step in this scenario? A.    Rescan the host to discover the new LUN location.B.    Remove the old path entries from the host.C.    Remove the previous owner and partner from the reporting nodes list.D.    Unmap the LUN, then remap the LUN. Answer: C QUESTION 19Click the Exhibit button.cl01::>iscsi portal showLogical Status CurrCurrVserver Interface TPGTAdmin/Oper IP Address NodePort Enabled---------- ---------- ---- ---------- ---------------- ----------- ---- -------svm1 1-a 1035 up/up192.168.1.66 cl01-01 e0a truesvm1 1-b 1051 up/up192.168.1.67 cl01-01 e0b truesvm1 2-a 1046 up/down192.168.1.68 cl01-02 e0a truesvm1 2-b 1052 up/up192.168.1.69 cl01-02 e0b trueReferring to the exhibit, which action would you take to troubleshoot the iscsi-2-a interface? A.    Verify that the iSCSI protocol is licensed for svm1.B.    Cycle the upstream switch port down and back up again.C.    Verify network connectivity between the host and LIF.D.    Verify that the iSCSI protocol is started on svm1. Answer: B QUESTION 20You want to verify that a host will be able to see the storage. A LUN is mapped to an igroup for the host, and both the host and storage are connected to FC switches.Which command will provide the path status information from the switch? A.    configureB.    cfgshowC.    fcpingD.    zoneshow Answer: B QUESTION 21Click the Exhibit button.cl01::> net int show -¬vserversvm1(network interface show)Logical Status NetworkCurrent Current IsVserver Interface Admin/OperAddress/Mask Node Port Home----------- --------- ---------- ------------------ ------------ ------ ----svm1fc_lif1 up/up20:0b:00:a0:98:4e:ba:14cl01-01 3a truefc_lif2 up/up20:0c:00:a0:98:4e:ba:14cl01-02 3a truelif1 up/up 172.16.21.31/24cl01-01 a0a truelif2 up/up 172.16.21.32/24cl01-02 a0a true4 entries were displayed.cl01::>Referring to the exhibit, a customer needs to move LIF "fc_lif1" to a new port.Which three actions must be performed to accomplish this task? (Choose three.) A.    Remove LIF from the existing portset.B.    Quiesce all hosts accessing LUNs over the LIF.C.    Take the LIF offline.D.    Update the switch zone to include the new WWPN.E.    Move the LIF to a new home port using thenetwork interface modifycommand. Answer: CDE QUESTION 22In a 4-node cluster, how many LIFs are required on each node to allow a host to use ALUA and have multiple optimized paths to each LUN? A.    1B.    2C.    4D.    6 Answer: B QUESTION 23Click the Exhibit button.cl01::>lun resize ¬-vserversvm1 ¬-volume db1_vol -¬lun db1-size 4096gError: command failed: Newsize exceeds this LUN'sinitial geometrycl01::>What is the reason for the error shown in the exhibit? A.    The LUN is thin provisioned, but the parent volume is thick provisioned and cannot satisfy the request.B.    The aggregate over commitment threshold has been exceeded.C.    The parent volume that contains the LUN is out of space.D.    The LUN cannot be grown past its maximum resize size. Answer: DExplanation:http://community.netapp.com/t5/VMware-Solutions-Discussions/lun-resize/td-p/8608 QUESTION 24You are asked to configure the Service Processor on a newly installed node, and must verify the following command:system-service processor network modify ¬-node local ¬-address-family IPv4 --enable true-ip-address 192.168.123.98 -¬netmask 255.255.255.0Which statement about this command is true? A.    -nodeshould reference the actual node name.B.    The gateway IP address is missing.C.    The Link Local IP Address is missing.D.    IPv6 is required for the SP. Answer: A QUESTION 25Inside of an SVM, an iSCSI IP address is defined on which object? A.    qtreeB.    LUNC.    LIFD.    node part Answer: CExplanation:https://library.netapp.com/ecmdocs/ECMP1196907/html/GUID-CEE760DF-A059-4018-BE6C-6B3A034CB377.html QUESTION 26Which protocol allows to access a controller's CLI interface? A.    SSHB.    NTPC.    TFTPD.    IMAP Answer: AExplanation:https://library.netapp.com/ecm/ecm_download_file/ECMP1196798(page 11) QUESTION 27Microsoft ODX supports which scenario on clustered Data ONTAP 8.3? A.    moving a VHDX with both SMB 3.0 and SAN protocols as either source or destinationB.    moving a VHDX from an SMB 3.0 source to an SMB 3.0 destination with no SAN supportC.    moving a VHDX from a SAN LUN source to a SAN LUN destination with no SMB supportD.    moving a VHDX with both SMB 2.1 and SAN protocols as either source or destination Answer: A QUESTION 28You are zoning a fabric for a clustered Data ONTAP storage system. After cabling, you see the following addresses logged into the fabric:20:04:00:a0:98:16:db:9c50:0a:09:83:8d:b1:ce:c3What should be included in the zone configuration? A.    50:0a:09:83:8d:b1:ce:c3 and the initiator WWNNB.    50:0a:09:83:8d:b1:ce:c3 and the initiator WWPNC.    20:04:00:a0:98:16:db:9c and the initiator WWPND.    20:04:00:a0:98:16:db:9c and the initiator WWNN Answer: C QUESTION 29A customer is experiencing slower than expected performance on a database connected to an iSCSI LUN. They are surprised that performance has decreased even though they have upgraded from a 1 GB to a 10 GB switch.What are three causes for this problem? (Choose three.) A.    Spanning Tree is incorrectly configured on the cluster nodes.B.    There is a faulty cable or SFP in the data path.C.    There is an MTU mismatch between the hosts, controllers, and switch.D.    Flow control is incorrectly set on either the host or controllers.E.    Routing is not set up between the iSCSI and cluster networks. Answer: ABC QUESTION 30Click the Exhibit button. A customer has deployed a new FAS8080EX running clustered Data ONTAP 8.3. Host A is running multipath software that has been properly configured. Also, Host A is currently accessing a LUN using the FC protocol stored on Node A. Switch A, shown in the exhibit, fails.What will happen next? A.    Node A will panic causing a storage failover to Node B.B.    Host A will lose all access to its LUN.C.    Host A will continue to access its LUN using Switch B through Node B.D.    Host A will continue to access its LUN using Switch B through Node A. Answer: B !!!RECOMMEND!!! 1.|2017 Version NS0-507 Exam Dumps (PDF & VCE) 528Q&As Download:http://www.braindump2go.com/ns0-507.html 2.|2017 Version NS0-507 Study Guide Video: YouTube Video: YouTube.com/watch?v=W4qwgESs2qA --------------------------------------------------- Images: --------------------------------------------------- --------------------------------------------------- Post date: 2017-03-10 02:08:40 Post date GMT: 2017-03-10 02:08:40 Post modified date: 2017-03-10 02:08:40 Post modified date GMT: 2017-03-10 02:08:40 ____________________________________________________________________________________________ Export of Post and Page as text file has been powered by [ Universal Post Manager ] plugin from www.gconverters.com